Modumax mk4 floor standing boiler

  • Stainless steel high efficiency, fully modulating condensing pre-mix floor standing boiler.

  • Available in 5 modules with outputs (@80/60°C) of 97, 116, 147, 196 and 254kW. Individual boiler modules can be stacked one, two or three high in 15 combinations up to 762kW output.

  • Hamworthy Web Icons JBs base set BLUE-47
  • Hamworthy Web Icons JBs base set BLUE-41
  • Hamworthy Web Icons JBs base set BLUE Product-icon-efficiency-95
  • Hamworthy Web Icons JBs base set BLUE-04
  • Hamworthy Web Icons JBs base set BLUE-06
  • Hamworthy Web Icons JBs base set BLUE-07
Modumax mk4 1
Modumax mk4 2
Modumax mk4 3
Modumax mk4 4
Modumax mk4 UHudd 03
New product

Product information

  • Fully modulating boiler which benefits from lower fuel usage and closer load matching.

  • Space-saving stacked modular boiler delivering 762kW in less than a square metre footprint.

  • Flexibility in system design with differential temperature (delta T) up to 40°C. Suited to district heating schemes, the lower flow rates associated with wider differential temperature allow smaller diameter pipes and smaller pumps that can lower capital cost and also reduce energy consumption.

  • Compensate for distribution losses in large heating systems with max 90°C flow temperature.

  • 10 bar maximum working pressure allows installation in basement for high rise buildings.

  • Stainless steel heat exchanger backed up by a 10-year warranty.

  • High relative velocity within the waterways help to reduce the opportunity for sedimentation.

  • Low water content, rapid response, with minimal standing losses.

  • Built in boiler sequence controls capable of controlling up to 16 boiler modules and hot water circuits.

  • Low environmental impact - NOx <40mg/kWh for maximum BREEAM credits.

  • Lightweight, fits through a standard doorway and can split into modules making Modumax mk4 ideal for limited access or rooftop plant rooms, as well as packaged plant rooms.

  • Buy in confidence from a UK manufacturer with decades of commercial heating and hot water expertise.

  • Back up and support from our team of experienced engineers across the UK.

  • Extensive boiler spare parts service available direct from the manufacturer.

  • BIM objects available to assist in design and management.

Modumax mk4 UHudd 09

Ideal uses/applications

Optional extras

  • Pipework kits with optional pumps to match the boiler model for ease of installation on site.

  • Flues available

  • Choose from a wide range of service contracts to help maintain optimum performance.

  • Book commissioning at the same time as placing your order for improved warranty terms.

Single Boiler Controls

  • Modbus gateway kit.

  • Outside air temperature sensor QAC34.

  • Domestic Hot Water sensor kit (sensor and pocket).

  • Mixing valve heating circuit control kit (clip in control module, temperature sensor and pocket) for 1 zone.

  • Programmable room sensor QAA75.

  • Offset adjustable room sensor QAA55.

Multiple Boiler Controls

  • Modbus gateway kit.

  • Outside air temperature sensor QAC34.

  • Volt free contact kit for remote status signalling AGU2.550A109.

  • Heating circuit sensor kit (sensor and pocket) QAZ36.

  • LPB Bus communication module OCI345, one required per boiler module.

  • Programmable room sensor QAA75.

Data Tables

  • Modumax mk4 commercial boiler

    Units

    97/97H

    97/194V

    97/291V

    116/116H

    116/232V

    116/348V

    147/147H

    147/294V

    147/441V

    196/196H

    196/392V

    196/588V

    254/254H

    254/508V

    254/762V

    No. of modules

    1

    2

    3

    1

    2

    3

    1

    2

    3

    1

    2

    3

    1

    2

    3

  • Energy

    Units

    97/97H

    97/194V

    97/291V

    116/116H

    116/232V

    116/348V

    147/147H

    147/294V

    147/441V

    196/196H

    196/392V

    196/588V

    254/254H

    254/508V

    254/762V

    Building regulations Part L seasonal efficiency

    % gross

    94.9

    94.9

    94.9

    93.1

    93.1

    93.1

    94.8

    94.8

    94.8

    93.9

    93.9

    93.9

    95.0

    95.0

    95.0

    BS EN 15502 seasonal efficiency

    % gross

    95.2

    95.2

    95.2

    93.4

    93.4

    93.4

    95.2

    95.2

    95.2

    94.1

    94.1

    94.1

    95.3

    95.3

    95.3

    Boiler output 80/60°C, NG & LPG

    kW

    95.7

    191.4

    287.1

    115.2

    230.4

    345.6

    142.8

    285.6

    428.4

    191.6

    383.2

    574.8

    239.8

    479.6

    719.4

    Boiler output 50/30°C, NG & LPG

    kW

    97.2

    194.4

    291.6

    116.2

    232.5

    348.7

    147.4

    294.8

    442.2

    196.3

    392.6

    588.9

    254.4

    508.7

    763.1

    Boiler input (gross) - maximum, NG

    kW

    109

    218

    327

    133

    266

    399

    163

    326

    489

    219

    428.7

    657

    275

    550

    825

    Boiler input (gross) - maximum, LPG

    kW

    106.7

    213.4

    320.1

    130.2

    260.4

    390.5

    159.5

    319.1

    478.6

    214.4

    428.7

    643.1

    269.2

    538.3

    807.5

    Boiler input (net) - maximum, NG & LPG

    kW

    98.2

    196.4

    294.6

    119.8

    239.6

    359.4

    146.8

    293.6

    440.3

    197.2

    394.4

    591.6

    247.6

    495.3

    742.9

    Boiler output - minimum 80/60°C, NG & LPG

    kW

    19.1

    19.1

    19.1

    23.5

    23.5

    23.5

    28.7

    28.7

    28.7

    38.6

    38.6

    38.6

    48.4

    48.4

    48.4

  • Water

    Units

    97/97H

    97/194V

    97/291V

    116/116H

    116/232V

    116/348V

    147/147H

    147/294V

    147/441V

    196/196H

    196/392V

    196/588V

    254/254H

    254/508V

    254/762V

    Water content

    litres

    16

    32

    48

    16

    32

    48

    22

    44

    66

    22

    44

    66

    22

    44

    66

    System design flow rate @ 40°C ∆T rise

    l/s

    0.6

    1.2

    1.8

    0.7

    1.4

    2.1

    0.9

    1.8

    2.7

    1.2

    2.4

    3.6

    1.5

    3

    4.5

    Water side pressure loss @ 40°C ∆T rise

    mbar

    5

    5

    5

    7

    7

    7

    36

    36

    36

    62

    62

    62

    100

    100

    100

    System design flow rate @ 30°C ∆T rise

    l/s

    0.8

    1.6

    2.4

    1

    2

    3

    1.2

    2.4

    3.6

    1.6

    3.2

    4.8

    2

    4

    6

    Water side pressure loss @ 30°C ∆T rise

    mbar

    9

    9

    9

    14

    14

    14

    60

    60

    60

    120

    120

    120

    180

    180

    180

    System design flow rate @ 20°C ∆T rise

    l/s

    1.2

    2.4

    3.6

    1.4

    2.8

    4.2

    1.8

    3.6

    5.4

    2.4

    4.8

    7.2

    3

    6

    9

    Water side pressure loss @ 20°C ∆T rise

    mbar

    20

    20

    20

    27

    27

    27

    145

    145

    145

    246

    246

    246

    395

    395

    395

    System design flow rate @ 11°C ∆T rise

    l/s

    2.2

    4.4

    6.6

    2.6

    5.2

    7.8

    3.3

    6.6

    9.9

    4.3

    8.6

    12.9

    5.4

    10.8

    16.2

    Water side pressure loss @ 11°C ∆T rise

    mbar

    61

    61

    61

    91

    91

    91

    500

    500

    500

    850

    850

    850

    1300

    1300

    1300

    Maximum water pressure

    barg

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    10

    Maximum flow temperature setting

    °C

    90

    90

    90

    90

    90

    90

    90

    90

    90

    90

    90

    90

    90

    90

    90

  • Gas

    Units

    97/97H

    97/194V

    97/291V

    116/116H

    116/232V

    116/348V

    147/147H

    147/294V

    147/441V

    196/196H

    196/392V

    196/588V

    254/254H

    254/508V

    254/762V

    Gas flow rate, NG (G20) - maximum

    m3/hr

    10.4

    20.8

    31.2

    12.7

    25.4

    38.1

    15.5

    31

    46.5

    20.9

    41.8

    62.7

    26.2

    52.4

    78.6

    Gas flow rate, LPG (G31) - maximum

    m3/hr

    4

    8

    12

    5

    10

    15

    6

    12

    18

    8.1

    16.2

    24.3

    10.1

    20.2

    30.3

    Nominal inlet pressure, NG (LPG) - maximum

    mbar

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    20 (37)

    Maximum gas inlet pressure NG (LPG)

    mbar

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

    25 (45)

  • Flue

    Units

    97/97H

    97/194V

    97/291V

    116/116H

    116/232V

    116/348V

    147/147H

    147/294V

    147/441V

    196/196H

    196/392V

    196/588V

    254/254H

    254/508V

    254/762V

    Approx. flue gas volume @ 15°C, 8.75-9.25% CO2

    m³/hr

    143

    286

    429

    160

    320

    480

    214

    428

    642

    279

    558

    837

    354

    708

    1062

    Maximum flue gas temperature @ 80/60°C

    °C

    83

    83

    83

    83

    83

    83

    78

    78

    78

    83

    83

    83

    82

    82

    82

    Pressure at boiler flue connection

    Pa mbar

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    150 1.5

    NOx emission (0% excess oxygen, dry air free) - NG

    mg/kWh

    39.8

    39.8

    39.8

    34.3

    34.3

    34.3

    37.7

    37.7

    37.7

    39.9

    39.9

    39.9

    38.8

    38.8

    38.8

    NOx emission (0% excess oxygen, dry air free) - LPG

    mg/kWh

    42

    42

    42

    57.3

    57.3

    57.3

    69.3

    69.3

    69.3

    68.6

    68.6

    68.6

    39.9

    39.9

    39.9

  • Connection

    Units

    97/97H

    97/194V

    97/291V

    116/116H

    116/232V

    116/348V

    147/147H

    147/294V

    147/441V

    196/196H

    196/392V

    196/588V

    254/254H

    254/508V

    254/762V

    Water flow/return connections

    inches

    G1½" male

    G1½" male

    G1½" male

    G1½" male

    G1½" male

    G1½" male

    G2½" male

    G2½" male

    G2½" male

    G2½" male

    G2½" male

    G2½" male

    G2½" male

    G2½" male

    G2½" male

    Gas inlet connection pipe thread size

    inches

    R1" male

    R1" male

    R1" male

    R1" male

    R1" male

    R1" male

    R1¼" male

    R1¼" male

    R1¼" male

    R1¼" male

    R1¼" male

    R1¼" male

    R1¼" male

    R1¼" male

    R1¼" male

    Nominal flue diameter (I/D)

    mm

    100

    180

    180

    100

    180

    180

    150

    250

    250

    150

    250

    250

    150

    250

    250

    Condensate trap connection(s) (O/D)

    mm

    32

    32

    32

    32

    32

    32

    32

    32

    32

    32

    32

    32

    32

    32

    32

  • Electrics

    Units

    97/97H

    97/194V

    97/291V

    116/116H

    116/232V

    116/348V

    147/147H

    147/294V

    147/441V

    196/196H

    196/392V

    196/588V

    254/254H

    254/508V

    254/762V

    Electrical supply

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    230 V 1 Ph 50 Hz

    Power consumption - maximum boiler modulation

    W

    166

    332

    498

    166

    332

    498

    240

    480

    720

    240

    480

    720

    240

    480

    720

    Start current (per module)

    Amp

    1.2

    1.2

    1.2

    1.2

    1.2

    1.2

    1.3

    1.3

    1.3

    1.3

    1.3

    1.3

    1.3

    1.3

    1.3

    Run current (per module)

    Amp

    0.72

    0.72

    0.72

    0.72

    0.72

    0.72

    1.05

    1.05

    1.05

    1.05

    1.05

    1.05

    1.05

    1.05

    1.05

    Approx shipping weight

    kg

    180

    355

    540

    180

    355

    540

    226

    452

    678

    226

    452

    678

    226

    452

    678

    Noise emission @1m @maximum modulation

    Max dB (A)

    60

    60

    60

    60

    60

    60

    65

    65

    65

    65

    65

    65

    65

    65

    65

    Noise emission @1m @minimum modulation

    Min dB (A)

    47

    47

    47

    47

    47

    47

    47

    47

    47

    47

    47

    47

    47

    47

    47

Relevant customer case studies

Downloads

Need help with your appliance? Download our guides for more technical information on your appliance.

Related Products

Frequently Asked Questions

What is Modumax mk4?

Modumax mk4 is the latest evolution of Hamworthy's floor-standing modular boiler. It keeps the established performance, reliability and modular capability of mk3 while introducing practical improvements to installation, usability and connectivity.

  • What is Modumax mk4?

    Modumax mk4 is the latest evolution of Hamworthy's floor-standing modular boiler. It keeps the established performance, reliability and modular capability of mk3 while introducing practical improvements to installation, usability and connectivity.

  • Who is Modumax mk4 designed for?

    It can support both new modular boiler projects and refurbishment/replacement projects. For new projects, the proposition centres on compact high output, modular flexibility, load matching and resilience. For existing Modumax installations, the same footprint and connection positions help make refurbishment straightforward.

  • Is mk4 simply a replacement for mk3?

    No. Modumax mk4 is the next evolution of the Modumax platform and is suitable for new modular projects as well as refurbishment. Where an existing mk3 is being replaced, the same footprint, connection positions, outputs and controls help minimise redesign and rework.

  • What's new compared with mk3?

    The main changes are a 7-inch touchscreen HMI, a new HMI status bar, reduced flue height on two- and three-stack boilers, a Modbus connectivity kit, VFC remote signalling supplied as standard, updated styling and an LPG conversion option.

  • What has stayed the same?

    Modumax mk4 carries forward the core Modumax proposition, including modular design, outputs and performance, familiar controls, footprint and connection positions. It is also available at the same list price as mk3.

  • Has performance changed?

    No. Modumax mk4 has the same outputs, efficiency and core performance as mk3.

  • Can Modumax mk4 replace an existing mk3?

    Yes. Modumax mk4 has the same footprint and connection positions as mk3, helping make replacement within an existing Modumax plantroom straightforward.

  • Will the existing pipework or plantroom layout need to change?

    For an mk3 replacement, having the same connection positions will minimise changes to existing pipework and avoid unnecessary redesign. Project-specific requirements should always be checked against the approved technical documentation.

  • What is the benefit of the reduced flue height?

    On two- and three-stack boilers, the flue height is approximately 240mm lower. This provides greater flexibility where plantroom or ceiling height is restricted.

  • Does mk4 reduce installation time?

    Modumax mk4 is simpler to install, particularly for refurbishment projects and where reduced flue height is beneficial. The exact installation time will depend on the individual project, so avoid quoting a fixed time saving.

  • Is there an additional product cost when moving from mk3 to mk4?

    No. Modumax mk4 is available at the same list price as mk3. Any project-specific accessories, conversion kits or installation requirements should be considered separately.

  • What is the benefit of the new touchscreen?

    The 7-inch touchscreen HMI provides faster, more intuitive navigation between screens, clearer fault visibility and easier system configuration.

  • Will existing mk3 users need to learn completely new controls?

    No. The controls, parameters and options remain familiar to mk3 users, helping keep the learning curve minimal.

  • What does the HMI status bar show?

    The new status bar provides clear visual indication of boiler status, helping make normal operation, standby and fault conditions easier to identify.

  • What is Modbus and why does it matter?

    A Modbus gateway kit allows the boiler or boilers to connect to a Modbus-enabled Building Management System or controller for monitoring and control.

  • What is VFC remote signalling?

    VFC remote signalling provides remote indication of normal operation and fault conditions. It is supplied as standard on mk4.

  • Can Modumax mk4 run on LPG?

    Yes. Modumax mk4 is dual-approved for Natural Gas and LPG.

  • How does LPG conversion work?

    Where LPG is required, a dedicated conversion kit enables on-site conversion without the need for a separate LPG-specific boiler variant.

  • What pipe kit options are available?

    Existing Modumax pipe kit options remain available, including DN100, DN150 and DN200 options across two- and three-stack configurations. Six additional kits are also available with matched primary pumps.

  • What are the key performance proof points?

    Modumax mk4 delivers outputs of up to 762kW from less than 1m², 5:1 turndown per module, up to 40°C ΔT, a 90°C maximum flow temperature, a stainless steel heat exchanger and a 10-year heat exchanger warranty.

  • Is mk4 designed and built in the UK?

    Yes. Modumax mk4 has been designed and built in Hull, with the UK market in mind.

  • Will mk3 continue to be supported?

    The current internal FAQ states that mk3 spare parts are planned to remain available until 2036.

  • Where can I find more detailed technical information?

    Refer to the Modumax mk4 product brochure, technical sheets and schematics. For project-specific questions, contact Darren Townend, Commercial Product Manager.