Baglioni Hotel, London
Read MoreWe're here to provide outstanding service and technical support for all our customers.
Are you looking for the most suitable commercial heating or hot water product for your next project?
Is there room for improvement in the efficiency of your plant room?
We understand that delivery is an important part of your project. Get in touch to discuss the details.
Contact your Area Sales Manager for help or advice with any of our commercial heating and hot water products.
Fully modulating boiler which benefits from lower fuel usage and closer load matching.
Space-saving stacked modular boiler delivering 762kW in less than a square metre footprint.
Flexibility in system design with differential temperature (delta T) up to 40°C. Suited to district heating schemes, the lower flow rates associated with wider differential temperature allow smaller diameter pipes and smaller pumps that can lower capital cost and also reduce energy consumption.
Compensate for distribution losses in large heating systems with max 90°C flow temperature.
10 bar maximum working pressure allows installation in basement for high rise buildings.
Stainless steel heat exchanger backed up by with a 10-year warranty, making the Wessex ModuMax mk3 an extremely robust boiler.
High relative velocity within the waterways help to reduce the opportunity for sedimentation.
Low water content, rapid response, with minimal standing losses.
Built in boiler sequence controls capable of controlling up to 16 boiler modules and hot water circuits.
Low environmental impact - NOx <40mg/kWh for maximum BREEAM credits.
Easy access to plant room as the lightweight and compact Wessex ModuMax mk3 fits through a standard doorway and can split into modules for limited access or rooftop plant rooms, as well as packaged plant rooms.
Buy in confidence from a UK manufacturer with decades of commercial heating and hot water expertise.
Back up and support from our team of experienced engineers across the UK.
Extensive boiler spare parts service available direct from the manufacturer.
BIM objects available to assist in design and management.
Hybrid systems alongside combined heat and power (CHP) and/or other low carbon technologies such as our commercial monobloc air source heat pumps.
Energy centres within district heating schemes and larger premises.
Housing developments and flats using district heating network.
Easy fit replacement for refurbishment projects.
Roof top and basement plantrooms.
Packaged plantrooms.
New build projects.
Large commercial and public buildings including schools, hospitals and hotels.
Medium sized commercial and public buildings including schools, hospitals, offices and hotels.
Small industrial and manufacturing premises.
Locations with substantial and continuous heating load including hospitals, care homes and hotels.
Pipework kits to match the boiler model for ease of installation on site.
Flues available
Choose from a wide range of service contracts to help maintain optimum performance.
Book commissioning at the same time as placing your order for improved warranty terms.
Single Boiler Controls
Outside air temperature sensor QAC34 (Part no. 533901457).
Domestic Hot Water sensor kit (sensor and pocket) (Part no. 563605674).
Mixing valve heating circuit control kit (clip in control module, temperature sensor and pocket) for 1 zone (Part no. 563605668).
Mixing valve heating circuit control kit (clip in control module, temperature sensor and pocket) for 2 zones (Part no. 563605669).
Mixing valve heating circuit control kit (clip in control module, temperature sensor and pocket) for 3 zones – Note: cannot be used in conjunction with volt free contact kit (Part no. 563605670).
Programmable room sensor QAA75 (Part no. 533901587).
Offset adjustable room sensor QAA55 (Part no. 533901589).
Multiple Boiler Controls
Outside air temperature sensor QAC34 (Part no. 533901457).
Volt free contact kit for remote status signalling AGU2.550A109 (Part no. 563605666).
Heating circuit sensor kit (sensor and pocket) QAZ36 (Part no. 563605673).
Merley boiler sequence controller, wall mounted (Part no. 563605672).
Merley boiler sequence controller, loose kit for panel mounting (Part no. 563605671).
LPB Bus communication module OCI345, one required per boiler module (Part no. 563605667).
Programmable room sensor QAA75 (Part no. 533901587).
Units | 97/97H | 97/194V | 97/291V | 116/116H | 116/232V | 116/348V | 147/147H | 147/294V | 147/441V | 196/196H | 196/392V | 196/588V | 254/254H | 254/508V | 254/762V | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of modules | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 |
Units | 97/97H | 97/194V | 97/291V | 116/116H | 116/232V | 116/348V | 147/147H | 147/294V | 147/441V | 196/196H | 196/392V | 196/588V | 254/254H | 254/508V | 254/762V | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Building regulations Part L seasonal efficiency | % gross | 94.9 | 94.9 | 94.9 | 93.1 | 93.1 | 93.1 | 94.8 | 94.8 | 94.8 | 93.9 | 93.9 | 93.9 | 95.0 | 95.0 | 95.0 |
BS EN 15502 seasonal efficiency | % gross | 95.2 | 95.2 | 95.2 | 93.4 | 93.4 | 93.4 | 95.2 | 95.2 | 95.2 | 94.1 | 94.1 | 94.1 | 95.3 | 95.3 | 95.3 |
Boiler output 80/60°C, NG & LPG | kW | 95.7 | 191.4 | 287.1 | 115.2 | 230.4 | 345.6 | 142.8 | 285.6 | 428.4 | 191.6 | 383.2 | 574.8 | 239.8 | 479.6 | 719.4 |
Boiler output 50/30°C, NG & LPG | kW | 97.2 | 194.4 | 291.6 | 116.2 | 232.5 | 348.7 | 147.4 | 294.8 | 442.2 | 196.3 | 392.6 | 588.9 | 254.4 | 508.7 | 763.1 |
Boiler input (gross) - maximum, NG | kW | 109 | 218 | 327 | 133 | 266 | 399 | 163 | 326 | 489 | 219 | 428.7 | 657 | 275 | 550 | 825 |
Boiler input (gross) - maximum, LPG | kW | 106.7 | 213.4 | 320.1 | 130.2 | 260.4 | 390.5 | 159.5 | 319.1 | 478.6 | 214.4 | 428.7 | 643.1 | 269.2 | 538.3 | 807.5 |
Boiler input (net) - maximum, NG & LPG | kW | 98.2 | 196.4 | 294.6 | 119.8 | 239.6 | 359.4 | 146.8 | 293.6 | 440.3 | 197.2 | 394.4 | 591.6 | 247.6 | 495.3 | 742.9 |
Boiler output - minimum 80/60°C, NG & LPG | kW | 19.1 | 19.1 | 19.1 | 23.5 | 23.5 | 23.5 | 28.7 | 28.7 | 28.7 | 38.6 | 38.6 | 38.6 | 48.4 | 48.4 | 48.4 |
Units | 97/97H | 97/194V | 97/291V | 116/116H | 116/232V | 116/348V | 147/147H | 147/294V | 147/441V | 196/196H | 196/392V | 196/588V | 254/254H | 254/508V | 254/762V | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Water content | litres | 16 | 32 | 48 | 16 | 32 | 48 | 22 | 44 | 66 | 22 | 44 | 66 | 22 | 44 | 66 |
System design flow rate @ 40°C ∆T rise | l/s | 0.6 | 1.2 | 1.8 | 0.7 | 1.4 | 2.1 | 0.9 | 1.8 | 2.7 | 1.2 | 2.4 | 3.6 | 1.5 | 3 | 4.5 |
Water side pressure loss @ 40°C ∆T rise | mbar | 5 | 5 | 5 | 7 | 7 | 7 | 36 | 36 | 36 | 62 | 62 | 62 | 100 | 100 | 100 |
System design flow rate @ 30°C ∆T rise | l/s | 0.8 | 1.6 | 2.4 | 1 | 2 | 3 | 1.2 | 2.4 | 3.6 | 1.6 | 3.2 | 4.8 | 2 | 4 | 6 |
Water side pressure loss @ 30°C ∆T rise | mbar | 9 | 9 | 9 | 14 | 14 | 14 | 60 | 60 | 60 | 120 | 120 | 120 | 180 | 180 | 180 |
System design flow rate @ 20°C ∆T rise | l/s | 1.2 | 2.4 | 3.6 | 1.4 | 2.8 | 4.2 | 1.8 | 3.6 | 5.4 | 2.4 | 4.8 | 7.2 | 3 | 6 | 9 |
Water side pressure loss @ 20°C ∆T rise | mbar | 20 | 20 | 20 | 27 | 27 | 27 | 145 | 145 | 145 | 246 | 246 | 246 | 395 | 395 | 395 |
System design flow rate @ 11°C ∆T rise | l/s | 2.2 | 4.4 | 6.6 | 2.6 | 5.2 | 7.8 | 3.3 | 6.6 | 9.9 | 4.3 | 8.6 | 12.9 | 5.4 | 10.8 | 16.2 |
Water side pressure loss @ 11°C ∆T rise | mbar | 61 | 61 | 61 | 91 | 91 | 91 | 500 | 500 | 500 | 850 | 850 | 850 | 1300 | 1300 | 1300 |
Maximum water pressure | barg | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Maximum flow temperature setting | °C | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
Units | 97/97H | 97/194V | 97/291V | 116/116H | 116/232V | 116/348V | 147/147H | 147/294V | 147/441V | 196/196H | 196/392V | 196/588V | 254/254H | 254/508V | 254/762V | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Gas flow rate, NG (G20) - maximum | m3/hr | 10.4 | 20.8 | 31.2 | 12.7 | 25.4 | 38.1 | 15.5 | 31 | 46.5 | 20.9 | 41.8 | 62.7 | 26.2 | 52.4 | 78.6 |
Gas flow rate, LPG (G31) - maximum | m3/hr | 4 | 8 | 12 | 5 | 10 | 15 | 6 | 12 | 18 | 8.1 | 16.2 | 24.3 | 10.1 | 20.2 | 30.3 |
Nominal inlet pressure, NG (LPG) - maximum | mbar | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) | 20 (37) |
Maximum gas inlet pressure NG (LPG) | mbar | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) | 25 (45) |
Units | 97/97H | 97/194V | 97/291V | 116/116H | 116/232V | 116/348V | 147/147H | 147/294V | 147/441V | 196/196H | 196/392V | 196/588V | 254/254H | 254/508V | 254/762V | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Approx. flue gas volume @ 15°C, 8.75-9.25% CO2 | m³/hr | 143 | 286 | 429 | 160 | 320 | 480 | 214 | 428 | 642 | 279 | 558 | 837 | 354 | 708 | 1062 |
Maximum flue gas temperature @ 80/60°C | °C | 83 | 83 | 83 | 83 | 83 | 83 | 78 | 78 | 78 | 83 | 83 | 83 | 82 | 82 | 82 |
Pressure at boiler flue connection | Pa mbar | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 | 150 1.5 |
NOx emission (0% excess oxygen, dry air free) - NG | mg/kWh | 39.8 | 39.8 | 39.8 | 34.3 | 34.3 | 34.3 | 37.7 | 37.7 | 37.7 | 39.9 | 39.9 | 39.9 | 38.8 | 38.8 | 38.8 |
NOx emission (0% excess oxygen, dry air free) - LPG | mg/kWh | 42 | 42 | 42 | 57.3 | 57.3 | 57.3 | 69.3 | 69.3 | 69.3 | 68.6 | 68.6 | 68.6 | 39.9 | 39.9 | 39.9 |
Units | 97/97H | 97/194V | 97/291V | 116/116H | 116/232V | 116/348V | 147/147H | 147/294V | 147/441V | 196/196H | 196/392V | 196/588V | 254/254H | 254/508V | 254/762V | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Water flow/return connections | inches | G1½" male | G1½" male | G1½" male | G1½" male | G1½" male | G1½" male | G2½" male | G2½" male | G2½" male | G2½" male | G2½" male | G2½" male | G2½" male | G2½" male | G2½" male |
Gas inlet connection pipe thread size | inches | R1" male | R1" male | R1" male | R1" male | R1" male | R1" male | R1¼" male | R1¼" male | R1¼" male | R1¼" male | R1¼" male | R1¼" male | R1¼" male | R1¼" male | R1¼" male |
Nominal flue diameter (I/D) | mm | 100 | 180 | 180 | 100 | 180 | 180 | 150 | 250 | 250 | 150 | 250 | 250 | 150 | 250 | 250 |
Condensate trap connection(s) (O/D) | mm | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 | 32 |
Units | 97/97H | 97/194V | 97/291V | 116/116H | 116/232V | 116/348V | 147/147H | 147/294V | 147/441V | 196/196H | 196/392V | 196/588V | 254/254H | 254/508V | 254/762V | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical supply | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | 230 V 1 Ph 50 Hz | |
Power consumption - maximum boiler modulation | W | 166 | 332 | 498 | 166 | 332 | 498 | 240 | 480 | 720 | 240 | 480 | 720 | 240 | 480 | 720 |
Start current (per module) | Amp | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 | 1.3 |
Run current (per module) | Amp | 0.72 | 0.72 | 0.72 | 0.72 | 0.72 | 0.72 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 | 1.05 |
Approx shipping weight | kg | 180 | 355 | 540 | 180 | 355 | 540 | 226 | 452 | 678 | 226 | 452 | 678 | 226 | 452 | 678 |
Noise emission @1m @maximum modulation | Max dB (A) | 60 | 60 | 60 | 60 | 60 | 60 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
Noise emission @1m @minimum modulation | Min dB (A) | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 | 47 |