Varmax floor standing boiler
- Floor standing, high output condensing boiler with a stainless steel heat exchanger.
- The range consists of 10 single boilers with outputs (at 50/30°C) of 127, 148, 191, 238, 290, 338, 415, 478, 558, 637kW.
Product information
Improved efficiency on split temperature systems due to high and low temperature return connections.
Non-dependent on system flow allowing wide differential temperatures.
Easier installation with no requirement for dedicated primary circuit and no minimum flow rates.
Tolerant to a wide range of system water conditions with a corrosion resistant stainless steel heat exchanger.
Long life backed up by a 5-year heat exchanger warranty.
Well insulated for low standby losses.
NOx emissions comply with ErP legislation lower than 56mg/kWh.
Match heating system loads accurately with outputs up to 637kW from a single boiler and ability to cascade multiple boilers.
Simplified flue system design as the flue gas non-return valve is built in to provide effective protection from re-circulation of flue gases through non-firing boilers.
Built in boiler sequence controls capable of controlling up to 16 boiler modules, multiple heating circuits and a hot water circuit using the master/slave principle.
Quick release access panels for ease of service and maintenance.
BIM objects available to assist in design and management.
Ideal uses/applications
Split temperature systems such as a combination of radiator loops/air convectors and underfloor heating.
Medium to large sized district heating schemes.
Optional extras
A large range of off the shelf flue options available
Room sealed and open flue solutions
Flue header kits
Single Boiler Controls
Outside air temperature sensor QAC34 (Part no. 533901457)
Domestic Hot Water sensor kit (sensor and pocket) QAZ36 (Part no. 563605674)
Mixing valve heating circuit control kit (AVS 75 control module, temperature sensor and pocket) for 1 zone (Part no. 059751)
Programmable room sensor QAA75 (Part no. 533901587)
Offset adjustable room sensor QAA55 (Part no. 533901589)
Multiple Boiler Controls
Outside air temperature sensor QAC34 (Part no. 533901457)
Heating circuit sensor kit (sensor and pocket) QAZ36 (Part no. 563605673)
Merley boiler sequence controller, wall mounted (Part no. 563605672)
LPB Bus communication module OCI345, one required per boiler module (Part no. 563605667)
Programmable room sensor QAA75 (Part no. 533901587)
Offset adjustable room sensor QAA55 (Part no. 533901589)
Choose from a wide range of service contracts to help maintain optimum performance.
Book commissioning at the same time as placing your order for improved warranty terms.
- Energy
Units
120
140
180
225
275
320
390
450
525
600
Building regulations Part L seasonal efficiency
% gross
96.13
96.13
96.33
96.33
96.24
96.24
96.22
96.22
96.22
96.22
Boiler output - maximum 80/60°C, NG & LPG*
kW
117
136
175
219
268
312
381
439
513
586
Boiler output - maximum 50/30°C, NG & LPG*
kW
127
148
191
238
290
338
415
478
558
637
Boiler output - minimum 80/60°C, Nat Gas.
kW
27.3
27.2
41.8
41.8
64.3
64.3
85
84.7
118
118
Boiler output - minimum 80/60°C, LPG
kW
38
37.8
61.3
61.3
87.6
87.7
N/A
N/A
N/A
N/A
Boiler input (gross) - maximum, NG & LPG*
kW
120
140
180
225
275
320
390
450
525
600
Boiler input (net) - maximum, NG & LPG*
kW
108
126
162
203
248
288
351
405
473
541
Standby loss
W
182
182
213
213
259
259
311
311
461
461
- Water
Units
120
140
180
225
275
320
390
450
525
600
Water content
litres
116
116
151
151
239
239
287
287
420
420
System design flow rate @ 30°C ΔT rise
l/s
0.9
1.1
1.4
1.7
2.1
2.5
3
3.5
4.08
4.69
Water side pressure loss @ 30°C ΔT rise
mbar
27
33
25
36
36
53
34
43
60
75
System design flow rate @ 20°C ΔT rise
l/s
1.4
1.6
2.1
2.6
3.2
3.7
4.6
5.3
6.14
7
Water side pressure loss @ 20°C ΔT rise
mbar
60
75
57
81
82
119
77
97
86
107
System design flow rate @ 11°C ΔT rise
l/s
2.5
2.9
3.8
4.7
5.8
6.8
8.3
9.5
11.17
12.77
Water side pressure loss @ 11°C ΔT rise
mbar
198
248
188
268
271
393
255
321
335
450
Minimum water pressure
barg
1
1
1
1
1
1
1
1
1
1
Maximum water pressure
barg
6
6
6
6
6
6
6
6
6
6
Minimum flow temperature setting
°C
22
22
24
24
20
20
23
23
22
22
Maximum flow temperature setting
°C
85
85
85
85
85
85
85
85
85
85
- Gas
Units
120
140
180
225
275
320
390
450
525
600
Gas flow rate, NG (G20) - maximum
m³/hr
12.7
14.8
19.1
23.8
29.1
33.9
41.3
47.6
55.6
63.5
Maximum gas inlet pressure, Nat Gas
mbar
25
25
25
25
25
25
25
25
25
25
Nominal inlet pressure, Nat Gas
mbar
20
20
20
20
20
20
20
20
20
20
Minimum gas inlet pressure, Nat Gas
mbar
17
17
17
17
17
17
17
17
17
17
Gas flow rate, LPG (G31) - maximum
m³/hr
4.9
5.7
7.4
9.2
11.3
13.1
N/A
N/A
N/A
N/A
Nominal inlet pressure, LPG
mbar
37
37
37
37
37
37
N/A
N/A
N/A
N/A
- Flue
Units
120
140
180
225
275
320
390
450
525
600
Maximum flue gas temperature @ 80/60°C Nat Gas
°C
60.8
62.1
61
62.3
61.7
63.4
62.5
64.8
64.4
66.6
Pressure at boiler flue spigot @ 80/60°C Nat Gas B23P
Pa
200
200
115
165
122
176
180
193
160
200
Maximum flue gas temperature @ 80/60°C LPG
°C
60.3
62.6
60.3
62.2
63
65.4
N/A
N/A
N/A
N/A
Pressure at boiler flue spigot @ 80/60°C LPG B23P
Pa
167
200
103
136
118
157
N/A
N/A
N/A
N/A
Dry NOx emission**
mg/kWh
30
30
30
30
40
40
35
35
55
55
NOx Class
6
6
6
6
6
6
6
6
6
6
- Electrical
Units
120
140
180
225
275
320
390
450
525
600
Electrical supply
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
230V, 1Ph, 50Hz
Power consumption - maximum boiler modulation
W
204
311
179
320
238
352
480
660
697
960
Start current (per module)
Amp
3.5
5.4
3.1
5.6
4.1
6.1
8.3
11.5
11.9
16.3
Run current (per module)
Amp
0.89
1.35
0.78
1.39
1.03
1.53
2.09
2.87
3
4.17
Approx shipping weight
kg
340
340
393
393
502
502
592
592
800
800
Noise emission @1m: @max. modulation
dB (A)
65
65
61
61
61
61
68
68
68
68
*390kW, 450kW, 525kW and 600kW models Nat Gas only
**(0% excess oxygen, mg/kWh dry air free); NG/LPG